Product Introduction
Medical incubators are widely used for storing drugs, reagents, vaccines, heating dialysate, physiological saline, and for the insulation and preservation of medical equipment in operating rooms. They are also used for heating physiological saline at 37 ℃ -42 ℃, flushing solution at 35 ℃ -37 ℃, mannitol at 37 ℃ -42 ℃, and ultrasound solution at 37 ℃ -42 ℃.
Technical indicators
1. ★ Electric heated tempered glass door: high transparency, strong observability, and prevention of low-temperature condensation.
2. The unique design of the air duct makes the temperature more uniform.
3. Anti slip and detachment partition design avoids sample detachment when pulling the partition.
4. ★ 7.0-inch color LCD touch screen, microcomputer temperature control system, real-time monitoring of temperature curve, menu style operation interface, simple and easy to understand, convenient for observation and operation.
5. ★ One screen query of running history, the display screen can switch between Chinese and English.
6. Possess three-level operation interface permissions (administrator, experimenter, operator).
7. Standard USB interface for real-time data storage.
8. Equipped with an interconnected PC interface, remote operation monitoring can be carried out, and a mobile APP control program can also be selected.
9. The liner is made of high-quality 304 mirror stainless steel. The special welding process ensures that the liner is not rusty and anti-aging, and is convenient for cleaning.
10. The inner cavity is wrapped in aluminum foil on all sides, and high-quality insulation boards are used to fill the gaps between the inner cavity and the partition. The heating is fast, the insulation effect is good, and the temperature is more uniform.
11. Protection of personnel - Install leakage current and overvoltage protectors.
12. Protection of samples - Equipped with an over temperature alarm, if the temperature inside the box exceeds the set over temperature, an alarm will be triggered.
13. Protection of the instrument - Add a temperature control switch. When the temperature is too high, the switch will disconnect to prevent damage to the instrument caused by excessive temperature.
14. Double layer tempered glass door - high temperature resistance, high reliability, fully tempered to ensure the safety of operators.
15. ★ Comes standard with UVC and lighting.
16. ★ Class II Medical Device Registration Certificate.
17. ★ Calibration certificate from Shandong Institute of Metrology (customized according to factory number).
Product parameters
Note:
1. The relevant data were measured at an ambient temperature of 25 ℃ and a relative humidity of no more than 85%.
2. The experiment shall be conducted after the equipment has been running stably for 2 hours.